Certificates

LGSR/2026/48203

5 Manor Avenue, Immingham · Wolds Electrical Services · officer Tom Ferriby

Data ExtractedDelivery: Pending

Certificate document

Source PDF received from the contractor

Electrical Installation Condition Report

BS 7671 · Requirements for Electrical Installations · 18th Edition

LGSR/2026/48203

Page 1 of 6

Section A — Details of the client

ClientLincolnshire Housing Partnership
AddressMarsden House, Grimsby
UPRN100031000137

Section B — Installation address

Address5 Manor Avenue, Immingham
PostcodeDN40 6HL
OccupierDavid Whitfield

Section C — Purpose of the report

PurposePeriodic inspection of the fixed electrical installation
Date of inspection27 Jul 2026
Records availableYes — previous EICR held on file

Section D — Summary of the condition of the installation

General conditionServiceable, no immediate danger identified
Overall assessmentUnsatisfactory
Next inspection recommended27 Jul 2031

Section E — Observations and recommendations

ItemObservationCode
1Bathroom supplementary bonding not verifiedC2
2No RCD protection on lighting circuitC3

Section F — Declaration

Inspected and tested byR. Okonkwo
On behalf ofWolds Electrical Services
Scheme registrationNICEIC 0284/1187

Signature

Date

27 Jul 2026

This document is a demonstration facsimile generated for the LHP Compliance Portal preview.

Extracted information

Read automatically from the document

Property
5 Manor Avenue, Immingham99%
Address
DN40 6HL · UPRN 10003100013797%
Inspector
R. Okonkwo95%
Inspection date
27 Jul 202699%
Expiry date
27 Jul 203198%
Overall result
Unsatisfactory96%
Risk level
High93%

Observations

  • C2Bathroom supplementary bonding not verified
  • C3No RCD protection on lighting circuit

Quality assurance

Automated policy checks run against every incoming certificate before an officer decision.

1 open finding
  1. Received
  2. 2Data Extracted
  3. 3QA Review
  4. 4Manager Approval
  5. 5Delivered

Extraction confidence

97.6%

Delivery audit trail

Every step from receipt to tenant download, timestamped for auditing

  1. Certificate created

    Received from contractor portal · CERT-5199

  2. Data extracted

    18 fields extracted · property matched on UPRN

  3. Compliance Review completed

    Automated checks run against LHP electrical policy